Compare our products

Lenstar 900
Applications
Cataract surgery
Refractive surgery
Anterior chamber analysis
IOL calculation
Premium IOL calculation
Myopia management
Biometry data
Biometry (AL, ACD, LT, CCT)
Keratometry (Dual zone anterior)
Anterior corneal topography
Posterior corneal topography
Pupillometry
White-to-white
Measurements
Technology OCLR
A-Scan biometry
Measurement pattern A-Scan
Access to A-scan
Access to B-scan
Standard deviation of repeated measurements
Anterior Chamber Depth (ACD)
Anatomic Anterior Chamber Depth (AD)
Vitrous Chamber Depth (VCD)
Keratometry measurements
Technology Dual-Zone Reflective Keratometry, 32 Marker Points
Spherical power
Astigmatism power and orientation
Flat meridian radius
Steep meridian radius
Flat meridian orientation
Steep meridian orientation
Topography measurements
Technology Optional Placido, 11-Ring
Anterior simulated keratometry
Posterior simulated keratometry
Corneal maps diameter (mm / inch) up to 6mm / up to 0.24 inches
Axial curvature map
Tangential curvature map
Spherical elevation map
Pachymetry map
Pupillometry measurements
Technology Infra-Red Photography
Pupil Diameter (PD)
Pupil center (barycenter)
White-to-white
Technology Hi-Res Color Photography
Iris diameter (ID)
Iris center (barycenter)
Measurement process
Eye positioning Semi automatic or manual
Eye tracking Automatic or manual
Dense cataract mode
Measurement mode selection
"Normal" eye
Aphakic eye
Pseudophakic eye
Silicone-filled eye
Mode combination
IOL calculation
Barrett Universal II
Barrett True-K Toric
Haigis
Hoffer Q
Holladay 1
SRK II and SRK/T
Masket / Modified Masket
Shammas No-History
IOL workflow
Personalization of IOL constants
Myopia management
AMMC by Kaymak
Axial Length Growth Speed
Axial Length Normative Data
Refractive Myopia Progression Prediction
Myopia Report for Parent Education
Software modules
EyeSuite Basic
EyeSuite Biometry (Cataract Suite)
EyeSuite Anterior Chamber Suite
EyeSuite IOL Toric Planner
EyeSuite Myopia
EyeSuite Myopia AMMC
Accessories
Instrument tables
Headrest
Chinrest
External PC (Windows only)
Networking
Electronic medical record interfaces (EyeSuite Script Language, GDT, EyeSuite Command Line Interface)
DICOM (SCU)
EyeSuite Viewing Stations
Connect to network printer
Connect to shared folder
Connect to remote database
Dimensions
Width (cm / inch) 31 cm / 12.2 inches
Depth (cm / inch) 26 cm / 10.23 inches
Height (cm / inch ) 42 cm / 16.53 inches
Electrical requirements
Line voltage 100-240V
Line frequency 50-60Hz
Safety certifications
Laser Class 1
● standard | ○ optional | − not available | □ not recommended

Global innovator in IOL power prediction

Through collaboration with leading surgeons

Since 2008, Haag-Streit has collaborated with renowned surgeons worldwide to enhance the outcomes of IOL power calculations in various scenarios, such as standard cases, toric lenses, and post-refractive situations. This extensive expertise has been integrated into EyeSuite IOL—Haag-Streit's software suite for IOL power calculations— and is continuously enhanced to incorporate the most up-to-date formulae available.

Leading technology

Staying at the forefront of biometry devices

Since 2008, Haag-Streit has been a pioneer in optical biometry devices, with the introduction of Lenstar 900 being one of the first. This technology revolutionized axial biometry measurements, providing faster and more precise results for eye care professionals. We continuously integrate state-of-the-art technologies like swept-source OCT in new products, like the Eyestar 900. In 2022, we further enhanced our products with the addition of the Anterior Chamber Suite.

Clinically validated

Excellent outcomes in any patient

Since its introduction in 2008, the prediction accuracy and excellent outcomes of the Lenstar 900 have been proven in more than 150* studies. With thousands of devices sold, millions of patients have enjoyed excellent outcomes when Lenstar 900 was part of their cataract planning process.

 

*Based on a PubMed search, 5 May 2023, Keyword “Lenstar 900”